Asus GigaX2124X/C Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Kommunikation Asus GigaX2124X/C herunter. Asus GigaX2124X/C User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 112
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 1 - GigaX Series

GigaX Series Layer 2 Managed Switch User Guide

Seite 2 - May 2005

GigaX Series L2 Managed Switch User Guide 10 List of Tables Table 1. Front panel labels and LEDs...15 Table 2

Seite 3

GigaX Series L2 Managed Switch User’s Guide 100 Figure 45. Using the ping utility If the target computer cannot be located, you will receive the mes

Seite 4 - ASUS contact information

GigaX Series L2 Managed Switch User Guide 101 7.1.2 nslookup You can use the nslookup command to determine the IP address associated with an Internet

Seite 5 - Table of Contents

GigaX Series L2 Managed Switch User’s Guide 102 7.2 Replacing defective fans Turn off the power of the switch when you remove the fan module on the

Seite 6

GigaX Series L2 Managed Switch User Guide 103 3. Carefully pull the two power cables from the fan connectors. 4. Loosens the screws that secure th

Seite 7

GigaX Series L2 Managed Switch User’s Guide 104 7.3 Simple fixes The following table lists some common problems that you may encounter when installing

Seite 8 - List of Figures

GigaX Series L2 Managed Switch User Guide 105 Problem Suggested Action Web Configuration Interface You forgot/lost your WEB Configuration Interface u

Seite 9

GigaX Series L2 Managed Switch User’s Guide 106 1000BASE-T A designation for the type of wiring used by Ethernet networks with a data rate of 1000 Mb

Seite 10 - List of Tables

GigaX Series L2 Managed Switch User Guide 107 filtering rule A rule that specifies what kinds of data the a routing device will accept and/or reject.

Seite 11 - 1 Introduction

GigaX Series L2 Managed Switch User’s Guide 108 mask See network mask. Multicast To send data to a group of network devices. Mbps Abbreviation for

Seite 12 - 1.2.3 Symbols

GigaX Series L2 Managed Switch User Guide 109 ping Packet Internet (or Inter-Network) Groper A program used to verify whether the host associated wit

Seite 13 - 2.1 Package contents

GigaX Series L2 Managed Switch User Guide 11 1 Introduction Congratulations on becoming the owner of the ASUS GigaX L2 managed switch! You may now man

Seite 14 - 2.2 Front Panel

GigaX Series L2 Managed Switch User’s Guide 110 SNMP Simple Network Management Protocol The TCP/IP protocol used for network management. STP Spannin

Seite 15

GigaX Series L2 Managed Switch User Guide 111 Telnet/SSH An interactive, character-based program used to access a remote computer. While HTTP (the we

Seite 16 - 2.4 Technical specifications

GigaX Series L2 Managed Switch User’s Guide 112 upstream The direction of data transmission from the user to the Internet. VLAN Virtual Local Area N

Seite 17 - 3 Quick start guide

GigaX Series L2 Managed Switch User Guide 12 • LEDs system, redundant power supply (RPS), and fan status 1.2 Conventions used in this document 1.2.1

Seite 18

GigaX Series L2 Managed Switch User Guide 13 2 Getting to know the GigaX 2124X 2.1 Package contents The GigaX 2124X switch package comes with the fol

Seite 19

GigaX Series L2 Managed Switch User Guide 14 2.2 Front Panel The front panel includes LED indicators that show the system, RPS, fan, and port status.

Seite 20

GigaX Series L2 Managed Switch User Guide 15 Table 1. Front panel labels and LEDs Label Color Status Description On Unit is powered on Green Flashi

Seite 21

GigaX Series L2 Managed Switch User Guide 16 2.3 Rear Panel The switch rear panel contains the ports for the data and power connections. Figure 3. R

Seite 22

GigaX Series L2 Managed Switch User Guide 17 3 Quick start guide This section provides the basic instructions to set up the GigaX environment. Refer

Seite 23 - 5.3.1 System Commands)

GigaX Series L2 Managed Switch User’s Guide 18 3.2 Part 2 — Setting up the switch Connect the device to the power outlet, and your computer or networ

Seite 24

GigaX Series L2 Managed Switch User Guide 19 Figure 4. Overview of Hardware Connections Console ManagementExpansion hub/switch LAN computersRPSRS-2

Seite 25 - <no password>

GigaX Series L2 Managed Switch User Guide 2 E2097 First Edition V1 May 2005 Copyright © 2005 ASUSTeK COMPUTER INC. All Rights Reserved. No part of th

Seite 26 - 4.2 Functional layout

GigaX Series L2 Managed Switch User’s Guide 20 Table 3. LED Indicators No. LED Description 1 System Solid green indicates that the device is turn

Seite 27

GigaX Series L2 Managed Switch User Guide 21 3. Make sure the settings of your terminal emulation software as follows: a) Choose the appropriate ser

Seite 28 - 4.2.1 Menu navigation tips

GigaX Series L2 Managed Switch User’s Guide 22 3.3.2 Setting up through the Web interface To successfully connect your PC to the switch, your PC must

Seite 29 - 4.3 System Pages

GigaX Series L2 Managed Switch User Guide 23 Default User Name: Admin Default Password: (no password) You can change the password at any time (se

Seite 30 - 4.3.2 IP Setup

GigaX Series L2 Managed Switch User’s Guide 24 4 Management with the Web Interface The switch provides Web pages that allow switch management through

Seite 31 - 4.3.3 Administration

GigaX Series L2 Managed Switch User Guide 25 Use the following defaults the first time you log into the program. You can change the password at any ti

Seite 32 - 4.3.5 Firmware Upgrade

GigaX Series L2 Managed Switch User’s Guide 26 4.2 Functional layout Typical web page consists of three separate frames. The top frame has a switch lo

Seite 33 - Figure 15. Firmware Upgrade

GigaX Series L2 Managed Switch User Guide 27 Figure 11. Expanded Menu List The right frame displays configuration pages or graphics for the statisti

Seite 34 - 4.4 Physical Interface

GigaX Series L2 Managed Switch User’s Guide 28 4.2.1 Menu navigation tips • To expand a group of related menus, click on the corresponding group nam

Seite 35

GigaX Series L2 Managed Switch User Guide 29 4.3 System Pages System pages include management, IP setup, administration, reboot, and firmware update f

Seite 36 - 4.5 Bridge

GigaX Series L2 Managed Switch User’s Guide 3 Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operatio

Seite 37 - 4.5.2 Link Aggregation

GigaX Series L2 Managed Switch User’s Guide 30 4.3.2 IP Setup The switch supports dynamic IP and static IP assignment. The dynamic IP is get from a DH

Seite 38

GigaX Series L2 Managed Switch User Guide 31 4.3.3 Administration The Administration page allows you enable or disable the authentication for web use

Seite 39 - 4.5.3 Mirroring

GigaX Series L2 Managed Switch User’s Guide 32 4.3.4 Reboot The Reboot page contains a button. Clicking the button reboots the system. Rebooting t

Seite 40

GigaX Series L2 Managed Switch User Guide 33 Figure 15. Firmware Upgrade

Seite 41 - 4.5.4 Static Multicast

GigaX Series L2 Managed Switch User’s Guide 34 4.4 Physical Interface The Physical Interface displays the Ethernet port status in real time. You can

Seite 42 - 4.5.6 Traffic Control

GigaX Series L2 Managed Switch User Guide 35 Figure 16. Physical Interface

Seite 43 - 4.5.7 Dynamic Addresses

GigaX Series L2 Managed Switch User’s Guide 36 4.5 Bridge The Bridge page group contains most layer 2 configurations, like link aggregation, STP etc..

Seite 44 - Figure 23. Dynamic Address

GigaX Series L2 Managed Switch User Guide 37 Edge Port: All ports are set to be edge ports by default. Edge port becomes STP port when BPDU is receive

Seite 45 - 4.5.8 Static Addresses

GigaX Series L2 Managed Switch User’s Guide 38 Port Selection Criterion: the algorithm to distribute packets among the ports of the link aggregation g

Seite 46 - 4.5.9 Tagged VLAN

GigaX Series L2 Managed Switch User Guide 39 same VLAN setting. • All the ports in the link aggregation group are treated as a single logical link. T

Seite 47

GigaX Series L2 Managed Switch User Guide 4 ASUS contact information ASUSTeK COMPUTER INC. (Asia-Pacific) Address: 150 Li-Te Road, Peitou, Taipei, Ta

Seite 48

GigaX Series L2 Managed Switch User’s Guide 40 The monitor port can not belong to any link aggregation group. The monitor port can not operate as a

Seite 49 - 4.5.11 CoS Queue Mapping

GigaX Series L2 Managed Switch User Guide 41 4.5.4 Static Multicast This page can add multicast addresses into the multicast table. The switch can hol

Seite 50 - 4.6 SNMP

GigaX Series L2 Managed Switch User’s Guide 42 4.5.5 IGMP Snooping IGMP snooping helps to reduce the multicast traffics on the network by allowing the

Seite 51 - 4.6.2 Host Table

GigaX Series L2 Managed Switch User Guide 43 Figure 22. Traffic Control 4.5.7 Dynamic Addresses This page displays the result of dynamic MAC addres

Seite 52 - 4.6.4 VACM Group

GigaX Series L2 Managed Switch User’s Guide 44 Figure 23. Dynamic Address

Seite 53 - 4.6.5 VACM View

GigaX Series L2 Managed Switch User Guide 45 4.5.8 Static Addresses You can add a MAC address into the switch address table. The MAC address added by

Seite 54

GigaX Series L2 Managed Switch User’s Guide 46 4.5.9 Tagged VLAN You can set up to 255 VLAN groups and show VLAN group in this page. There is a defaul

Seite 55 - 4.6.6 USM User

GigaX Series L2 Managed Switch User Guide 47 Figure 25. Tagged VLAN

Seite 56 - Figure 33. USM User

GigaX Series L2 Managed Switch User’s Guide 48 4.5.10 Default Port VLAN and CoS Some VLAN tag related field settings for each port are included in th

Seite 57 - 4.7 Security

GigaX Series L2 Managed Switch User Guide 49 4.5.11 CoS Queue Mapping The switch supports 4 egress queues for each port with a strict priority sched

Seite 58 - 4.7.2 Dial-In User

GigaX Series L2 Managed Switch User Guide 5 Table of Contents 1.1 L2 managed features ...11 1.2 Co

Seite 59 - 4.7.3 RADIUS

GigaX Series L2 Managed Switch User’s Guide 50 4.6 SNMP This group offers the SNMP configuration including Community Table, Host Table, and Trap Setti

Seite 60

GigaX Series L2 Managed Switch User Guide 51 4.6.2 Host Table This page links host IP address to the community name that is entered in Community Table

Seite 61 - 4.8 VCT

GigaX Series L2 Managed Switch User’s Guide 52 4.6.3 Trap Setting By setting trap destination IP addresses and community names, you can enable SNMP tr

Seite 62 - 4.9 Statistics Chart

GigaX Series L2 Managed Switch User Guide 53 Security Model: enter the Security Model Name that the Group belongs. Any is suitable for v1,v2,v3. USM i

Seite 63 - 4.9.3 Historical Status

GigaX Series L2 Managed Switch User’s Guide 54 View Type: select the View Type that the View belongs. Included or Excluded when View Subtree matches t

Seite 64 - 4.10 Save Configuration

GigaX Series L2 Managed Switch User Guide 55 4.6.6 USM User USM (User-based Security Model) User is used to configure the information of SNMPV3 USM Us

Seite 65 - 5 Console Interface

GigaX Series L2 Managed Switch User’s Guide 56 Figure 33. USM User

Seite 66 - 5.1 Power On Self Test

GigaX Series L2 Managed Switch User Guide 57 4.7 Security The switch has the 802.1x port-based security feature. Only authorized hosts are allowed to

Seite 67 - 5.1.1 Boot ROM Command Mode

GigaX Series L2 Managed Switch User’s Guide 58 • Multi-host: If enabled, all hosts connected to the selected port are allowed to use the port if one

Seite 68 - 5.1.2 Boot ROM Commands

GigaX Series L2 Managed Switch User Guide 59 • User Name: New user name. • Password: Password for the new user. • Confirm Password: Enter the pas

Seite 69 - 5.3 CLI Commands

GigaX Series L2 Managed Switch User Guide 6 4.3.5 Firmware Upgrade ...32 4.4 Physical Interface ...

Seite 70

GigaX Series L2 Managed Switch User’s Guide 60 • Authentication Server IP: The IP address of the RADIUS server. • Authentication Server Port: The p

Seite 71

GigaX Series L2 Managed Switch User Guide 61 4.8 VCT VCT stands for "Virtual Cable Tester". The major function of VCT is to detect cable fau

Seite 72

GigaX Series L2 Managed Switch User’s Guide 62 4.9 Statistics Chart The Statistics Chart pages provide network flow in different charts. You can speci

Seite 73 - 5.3.3 Bridge Commands

GigaX Series L2 Managed Switch User Guide 63 Figure 39. Error group 4.9.3 Historical Status You can display information for different ports and stat

Seite 74

GigaX Series L2 Managed Switch User’s Guide 64 4.10 Save Configuration To save configuration permanently, you should click . The setting also takes

Seite 75

GigaX Series L2 Managed Switch User Guide 65 5 Console Interface This chapter describes how to use console interface to configure the switch. The swit

Seite 76

GigaX Series L2 Managed Switch User’s Guide 66 5.1 Power On Self Test POST is executing during the system booting time. It tests system memory, LED a

Seite 77

GigaX Series L2 Managed Switch User Guide 67 5.1.1 Boot ROM Command Mode During the POST process, you can enter a “Boot ROM Command” mode by pressing

Seite 78

GigaX Series L2 Managed Switch User’s Guide 68 5.1.2 Boot ROM Commands Type “?” in the boot mode to display the valid commands list. Table 6. Boot R

Seite 79

GigaX Series L2 Managed Switch User Guide 69 5.2 Login and Logout By typing “login” to enter the CLI mode, you have to give a valid user name and pas

Seite 80

GigaX Series L2 Managed Switch User Guide 7 5.1 Power On Self Test...66 5.1.1 Boot ROM Command

Seite 81 - 5.3.4 SNMP

GigaX Series L2 Managed Switch User’s Guide 70 If you put a name in the name description field, the switch system name will be changed into the new on

Seite 82

GigaX Series L2 Managed Switch User Guide 71 Figure 44. SYS commands [VLAN ID] Display the VLAN ID for the switch. It is necessary to be within the s

Seite 83

GigaX Series L2 Managed Switch User’s Guide 72 [New Password] [Verify Password] The default user name is admin. By default, a password is not required

Seite 84

GigaX Series L2 Managed Switch User Guide 73 [Flow Control] [Enable/Disable] Displays the IEEE802.3x flow control setting of a port. Note that this fl

Seite 85

GigaX Series L2 Managed Switch User’s Guide 74 [Priority] [Path Cost] [Edge Port] [Point-to-point] Displays the current STP/RSTP ports parameters sett

Seite 86

GigaX Series L2 Managed Switch User Guide 75 CLI command : l2 trunk rtag <1|2|3> Rtag values and corresponding meanings: 1: source XOR destinati

Seite 87

GigaX Series L2 Managed Switch User’s Guide 76 CLI command : l2 port lacppri <priority> <port list / * for all ports>[ Reload] Restores th

Seite 88

GigaX Series L2 Managed Switch User Guide 77 untagged port list [format: 1 2 3 4-50/* for all ports]: <untagged port list> [Remove Multicast Gr

Seite 89 - 5.3.5 Security Commands

GigaX Series L2 Managed Switch User’s Guide 78 [Limit] Displays the current rate limitation value of the switch. User can change this value by giving

Seite 90

GigaX Series L2 Managed Switch User Guide 79 [MAC Address] [VLAN ID] [Port Selection] [Discard] [none/source/destination/source & destination] Use

Seite 91

GigaX Series L2 Managed Switch User Guide 8 List of Figures Figure 1. GigaX L2 managed switch package contents...13 Figure 2. Front pan

Seite 92

GigaX Series L2 Managed Switch User’s Guide 80 CLI command : l2 vlan create <vlan id> <vlan name> <port list> CLI command : l2 vlan

Seite 93 - Miscellaneous Commands

GigaX Series L2 Managed Switch User Guide 81 [Reload] Restores the previous saved settings from configuration file. CLI command : l2 port retrieve [Co

Seite 94 - Subnets

GigaX Series L2 Managed Switch User’s Guide 82 CLI command : snmp community set Community entry (table index): <entry id to config> Community st

Seite 95 - Class C Network ID Host ID

GigaX Series L2 Managed Switch User Guide 83 User can modify a host entry in the table by reassigning its allowed IP address, network mask and communi

Seite 96 - 6.1.2 Network classes

GigaX Series L2 Managed Switch User’s Guide 84 CLI command : snmp trap set Trap table entry (table index): <entry id to config> SNMP version? (1

Seite 97 - 6.2 Subnet masks

GigaX Series L2 Managed Switch User Guide 85 Security Level [1/2/3](noauth/authnopriv/authpriv): <security level> Context Match [0/1](inexact/ex

Seite 98

GigaX Series L2 Managed Switch User’s Guide 86 CLI command : snmp snmpv3 access retrieve [View Name] [View Type] [View Subtree] [View Mask] VACM (View

Seite 99 - 7 Troubleshooting

GigaX Series L2 Managed Switch User Guide 87 [Reload] Restores the previous saved settings from configuration file. CLI command : snmp snmpv3 view ret

Seite 100

GigaX Series L2 Managed Switch User’s Guide 88 Name: (old user name string ) < new user name string > AuthProtocol [oid]: (old auth protocol oid

Seite 101 - 7.1.2 nslookup

GigaX Series L2 Managed Switch User Guide 89 5.3.5 Security Commands [Reauthentication] Allows user to open or close periodic reauthentication. CLI

Seite 102

GigaX Series L2 Managed Switch User Guide 9 Figure 26. Default Port VLAN and CoS... 48 Figure 27. Cos Queue

Seite 103

GigaX Series L2 Managed Switch User’s Guide 90 [Multi-host] Allows user to enable or disable Multi-host on some specific ports. CLI command : security

Seite 104 - 7.3 Simple fixes

GigaX Series L2 Managed Switch User Guide 91 Dynamic VLAN: <dynamic VLAN> CLI command : security dialinuser remove <user name/*> Allows us

Seite 105 - 8 Glossary

GigaX Series L2 Managed Switch User’s Guide 92 [Reload] Restores the previous saved settings from configuration file. CLI command : security radius r

Seite 106

GigaX Series L2 Managed Switch User Guide 93 Miscellaneous Commands sys uptime: shows the time since the system boot up. sys date: shows the current d

Seite 107

GigaX Series L2 Managed Switch User’s Guide 94 6 IP Addresses, Network Masks, and Subnets 6.1 IP Addresses This section pertains only to IP addresse

Seite 108

GigaX Series L2 Managed Switch User Guide 95 Table 7. IP address structure Field1 Field2 Field3 Field4 Class A Network ID Host ID Class B Networ

Seite 109

GigaX Series L2 Managed Switch User’s Guide 96 6.1.2 Network classes The three commonly used network classes are A, B, and C. (There is also a class D

Seite 110

GigaX Series L2 Managed Switch User Guide 97 6.2 Subnet masks A mask looks like a regular IP address, but contains a pattern of bits that tells what

Seite 111

GigaX Series L2 Managed Switch User’s Guide 98 The two extra bits in Field 4 can have four values (00, 01, 10, 11), so there are four subnets. Each su

Seite 112

GigaX Series L2 Managed Switch User Guide 99 7 Troubleshooting This section gives instructions for using several IP utilities to diagnose problems. A

Kommentare zu diesen Handbüchern

Keine Kommentare