ASUS DSBF-DM Seriies 5-25
5.2.6 Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected logical
drive. The utility can automatically detect and/or detect and correct any differences
in data redundancy depending on the selected option in the
Objects
>
Adapter
menu.
The
Check Consistency
command is available only for logical drives included
in a RAID 1 set.
Using the Check Consistency
To check data consistency using the
Check Consistency
command:
1. From the
Management Menu
, select
Check Consistency
, then press
<Enter>.
2. The screen displays the available RAID set(s) and prompts you to select the
logical drive to check. Press the <Spacebar> to select the logical drive from
the
Logical Drive
selection, then press <F10>.