ASUS PIKE 2208 2-41
2. Scenario #2: If some of the drives in a conguration are removed
and re-inserted, the controller considers the drives to have foreign
congurations.
Import or clear the foreign conguration. If you select Import, automatic
rebuilds will occur in redundant virtual drives.
Start a consistency check immediately after the rebuild is complete to ensure
data integrity for the virtual drives.
3. Scenario #3: If all the drives in a virtual drive are removed, but at
different times, and re-inserted, the controller considers the drives to
have foreign congurations.
Import or clear the foreign conguration. If you select Import, all drives
that were pulled before the virtual drive became ofine will be imported
and then automatically rebuilt. Automatic rebuilds will occur in redundant
virtual drives.
4. Scenario #4: If the drives in a non-redundant virtual drive are removed,
the controller considers the drives to have foreign congurations.
Import or clear the foreign conguration. No rebuilds will occur after
the import operation because there is no redundant data to rebuild the
drives with.