physICal drIve probleMs
Physicaldrivesarethefoundationofdatastorage.AphysicaldriveproblemcanaffectyourentireRAIDsystem.
When a yellow ! icon or a red X iconappearsbesideaphysicaldrive,checkthedrive’soperationalstatus:
1. ClicktheDevicetab.
2. ClickthePhysicalDriveicon.
3. Clickthephysicaldriveyouwant,thenclicktheViewbutton.
LookunderOperationalStatusfortheconditionofthephysicaldrive.
• Ofine–Checkthedrivefor:
PFA Condition–Causedbyabadblockorsector.SeeNote1below.
Stale Condition–Causedbyobsoletearrayinformationonthephysicaldrive.SeeNote2below.
• Not Usable–Thisconditionoccurswhenyouhave:
TwocontrollersinyourRAIDsubsystemandaSATAdrivewithoutaSAS-to-SATAadapter.SeeNote3below.
AmissingordefectiveSAScablebetweentheRAIDsubsystemandaJBODexpansionunit.
• Drive Failed or Dead–Thephysicaldrivecannotberepaired.
Youmustreplacethefaileddrive.SeeNote4below.
Note1:Cleartheerrorcondition.Thenthephysicaldriveisavailable.See“ClearingaStaleoraPFACondition”
Note2:Identifythediskarraytowhichthephysicaldrivebelongs.Thendeletethediskarray.Ifthe error
conditionremainsonthephysicaldrive,cleartheerrorcondition.
Note3:ObtainSAS-to-SATAadaptersthoughASUSStorageTechnology,at
http://www.ASUSStorage.com.
Note4:YoucansetthenumberofbadblockstoleratedbeforethecontrollermarksaphysicaldriveasDead.
dIsk array and loGICal drIve probleMs
Disk array and logical drive problems include:
• "Disk Array Degraded / Logical Drive Critical" on page 213
• "DiskArrayOfine/LogicalDriveOfine"onpage214
• "RepairinganOfineDiskArrayorLogicalDrive"onpage214
• "Rebuilding a Disk Array" on page 215
• "Incomplete Array" on page 215
Diskarrayproblemstypicallyresultfromaphysicaldrivefailure.Themostcommonproblemisadegradeddisk
array.TheRAIDcontrollercanrebuildadegradeddiskarray.
DISk array DeGraDeD / loGIcal DrIve crItIcal
Diskarraysaremadeupofphysicaldrives.Logicaldrivesarecreatedonthediskarray.
When one of the physical drives in a disk array fails:
• The operational status of the disk arraybecomesCritical.
• The operational status of the logical drivesbecomesCriticalorDegraded.
• The operational status of the physical drive becomes Dead or Ofine.
ASUS Storage Management reports these conditions in the following places:
• Dashboard tab
A yellow ! iconbesidethediskarrays,logicaldrives,andphysicaldrivesunderSystemStatus.
MajoreventforthelogicaldriveunderEventInformation.
WarningeventforthephysicaldriveunderEventInformation.
• Device tab
Front View – Physical drives are shown Dead or Ofine and marked with a red X icon,orMissing.
Physical Drive View – Physical drives are shown Dead or Ofine and marked with a red X icon,or
Missing.