45 • Schlage • Schlage Utility Soware User's Guide
Controller PropertiesAD-Series Locks and Controllers
CT5000
EDIT Tab
Property Description Default
Lock Type Classroom: Unlocks when a credential is presented and then automatically locks aer
the relock delay has expired. The CT5000 can only be Classroom Type.
Classroom
PIN Length Maximum number of digits in the user PIN. Range of 3 to 6 digits. 6
Ignore Keypad If checked, key entry codes are ignored. Disabled
Relock Delay Amount of time before the CT5000 relocks aer being unlocked by a user presenting
a valid credential or the Request to Exit being released.
3 seconds
CT5000-Input
Request to Exit: Active
Open/Active Closed
This sets the polarity of the Request To Exit signal into the CT5000. Default is when
the switch is closed and the CT5000 reads and reports a Request to Exit.
Active close
CT5000-Input
Reader Tamper 1:
Active Open/Active
Closed
This sets the polarity of the Reader 1 Tamper signal into the CT5000. Default is when
the switch is closed and the CT5000 reads and reports a Reader 1 Tamper.
Active close
CT5000-Input
Reader Tamper 2:
Active Open/Active
Closed
This sets the polarity of the Reader 2 Tamper signal into the CT5000. Default is when
the switch is closed and the CT5000 reads and reports a Reader 2 Tamper.
Active close
Door Position Switch
(DPS): Installed
If unchecked, the Door Position Switch (DPS) is disabled and the Door Prop Delay,
Anti-Tailgate, Request to Exit Clears Alarm, and Alarm are also disabled.
By default, the CT5000 assumes there is no Door Position Switch (DPS) connected.
Disabled
Door Position Switch
(DPS): Active Open/
Active Closed
This sets the polarity of the Door Position Switch (DPS) signal into the CT5000
(Open or Closed). Default is when the switch is closed and the CT5000 reads and
reports the door closed.
Active Open
Door Prop Delay The Prop Delay setting is the time to allow the door to be held open before the alarm
relay triggers the alarm.
30 seconds
Door Prop Delay:
Enabled/Disabled
When enabled, the alarm relay will activate aer the door has been open more time
than the number of seconds specified in the Door Prop Delay time.
Disabled
Anti-Tailgate Anti-Tailgate is designed to automatically relock the door when the door re-closes, no
matter how much time is le on the relock delay (requires a Door Position Switch).
Disabled
Request to Exit Clears
Alarm
During an alarm event, enabling request to exit disables the alarm. Disabled
Alarm Relay:
Normally Open
(Secure)
Normally Closed
(Secure)
When Normally-closed (Secure), the normally-closed side of the relay is the secure
side. (The alarm relay polarity will change as soon as saved, a credential is not
required.)
Normally
Closed
(Secure)
Aux Relay:
Normally Open
(Secure) Normally
Closed (Secure)
When Normally-closed (Secure), the normally-closed side of the relay is the secure
side. (The auxiliary relay polarity will change as soon as saved, a credential is not
required.)
Normally
Closed
(Secure)
Strike Relay:
Normally Open
(Secure)
Normally Closed
(Secure)
When Normally-closed (Secure), the normally-closed side of the relay is the secure
side. (Needs to read a valid credential before changing the relay polarity.)
Normally
Closed
(Secure)