50 • Schlage • Schlage Utility Soware User's Guide
Lock PropertiesCO-Series Locks
CO-200/220/250
EDIT Tab
Property Description Default
Lock Type Classroom Security (CO-220 Only): Allows lock to be placed into secure lockdown
by the a paired fob. Once in lockdown, only a Passthrough credential can be used to
gain access.
Oce: Unlocks when a credential is presented and then automatically locks aer the
relock delay has expired. To keep the door unlocked, push the button on the inside.
The button will momentarily illuminate green. To return the lock to the locked state,
push the button again or present a credential to the outside.
Privacy: To initiate the Privacy function, with the door closed, push the button on the
inside of the door. This prevents normal credentials from opening the door from the
outside.
The lock will go back to its normal state when the button is pushed again or when the
door position switch indicates that the door has opened.
When using a Mortise Deadbolt, extending the deadbolt from the inside lights a
red LED on the inside trim and initiates the Privacy function which prevents normal
credentials from opening the door from the outside. The lock can always be opened
using a Pass-Through credential or mechanical key in case of emergency.
Storeroom: Lockset is normally secure. Inside lever always allows free egress. Valid
Toggle credentials may be used to alternate (toggle) the state of the lock between
passage (unlocked) and secured (locked). Unlocks when a normal credential is
presented and then automatically locks aer the relock delay has expired.
Set by the
Factory
PIN Length
(CO-200/220 only)
Maximum number of digits in the user PIN. Range of 3 to 6 digits. 6
Allow Privacy Mode
Override
(CO-250 only)
When enabled, allows cards override a lock that has been placed in privacy mode.
When disabled, only cards specifically assigned to this door will have access.
Disabled
Ignore Keypad If checked, key entry codes are ignored. Disabled
Record Lock/Unlock
1
If checked and supported by the system soware, will record an audit event when the
Inside Push button is pressed.
Disabled
Disable Interior Button
LED
1
If checked, interior button LED blinking is disabled. Disabled
(unchecked)
Battery Fail Mode Lock state set when battery fails. As-Is, Secure/Locked, Unsecure/Unlocked As-Is
Coin Cell Battery
Nuisance Delay
Lock state set aer coin cell battery replacement. If unchecked, nuisance delay is
disabled.
Enabled
Relock Delay Amount of time before the lock relocks aer being unlocked by a user presenting a
valid credential.
3
ADA Delay Amount of time before the lock relocks aer being unlocked by a user who is flagged
as handicapped and presenting a valid credential. Can be changed in the access
control system.
30
READER Tab
Property Description Default
Prox in Use Proximity credential card types allowed. Selections: HID, GE/CACY, AWID ALL selected
Mag Track in Use Magnetic card track that access data is to be read from. Track 1, 2 or 3 (Track 1 not
configurable for AD-200)
Track 2
Enable Low Power
Wake-Up
Active when Mag Track 1 or 3 is selected in "Mag Track in Use". By enabling Low Power
Wake-Up and recording data on track 2, this option will allow longer battery life.
Enabled
Beeper Indicates if the Beeper is on or off. ON
1. This feature is not available on the CO-220 Safe School Lock.